Are your rotary steerable tools performing at optimal performance?
Read our latest white paper about the primary operational differences and similarities of push-the-bit tools by Thomas M. Bryant of APS.

Surface System Hardware

MWD Surface System Hardware

Designed to expand with your operations

APS’s SureShot™ MWD family includes our modular approach to building MWD decoding and logging systems according to your business’s changing needs.

The base model of our expandable SureShot surface system is the Sensor Interface Unit 2 (SIU 2.5), which includes everything needed to measure, filter, decode, display, store, retrieve, transmit and remotely access data for basic survey jobs. A separate PC and rig floor display can be added when needed for full directional MWD capability, and a depth tracking system (DTS) SIU 2.5 retrofit and Printrex plotter can be added for LWD service, when required.

SureShot’s intuitive, menu-based operating system allows you to lock-out some parameter changes while allowing the field engineer to still make necessary adjustments on the job. SureShot systems are available in both “ruggedized” and “lite” versions.

SIU
SIU Laptop
SIU Laptop Software
SWIPE TO SCROLL
Application MWD Tool Gamma Sensor SIU 2.5 SIU 2.5 with DTS option PC* with SureShot Software Printrex Plotter Rig Floor Display Surface Sensors**
Pressure Hook Load Depth
Survey-on-connection              
MWD          
Gamma/LWD  
APS’s modular approach to building MWD decoding and logging systems
are designed to adapt to your business’s needs.

Tool Specifications

Surface System Hardware Technical Data Sheet

General Specs
Application

General Specifications

Surface System
SIU 2.5 & Plotter General Specifications
Electrical Requirements 100 - 240 VAC, 50 - 60 Hz, 13 W
Operating Temperatures 32˚ to 158˚F 0˚ to 70˚C
Storage Temperatures 14˚ to 185˚F -10˚ to 85˚C
“Ruggedized” System
Directional Case – 19 in. EIA Standard
17 in. (h) x 27 in. (w) x 34.25 in. (d)
Weight – 119 lb
Case – 483 mm EIA Standard
482 mm (h) x 686 mm (w) x 870 mm (d)
eight – 54.0 kg
Directional & Depth Tracking Case – 19 in. EIA Standard
17 in. (h) x 27 in. (w) x 34.25 in. (d)
Weight – 119 lb
Case – 483 mm EIA Standard
482 mm (h) x 686 mm (w) x 870 mm (d)
Weight – 54.0 kg
“Lite” System
Directional 3.5 in. (h) x 19 in. (w) x 16 in. (d)
Weight – 12 lb plus laptop
89 mm (h) x 483 mm (w) x 406 mm (d)
Weight – 5.4 kg plus laptop
Directional & Depth Tracking 3.5 in. (h) x 19 in. (w) x 16 in. (d)
Weight – 12 lb plus laptop
89 mm (h) x 483 mm (w) x 406 mm (d)
Weight – 5.4 kg plus laptop
Printrex Plotter
  7.25 in. (h) x 22 in. (w) x 20 in. (d)
Weight – 37 lb
184 mm (h) x 559 mm (w) x 508 mm (d)
Weight – 16.8 kg
Rig Floor Displays
Standard Certified Zone 1 Division 2; 9 in.; wireless
-4˚ to 140˚F (-20˚ to 60˚C) operating; -40˚ to 167˚F (-40˚ to 75˚C) storage
Low-temperature Certified Zone 1 Division 2; 15 in.; wired/wireless
-40˚ to 122˚F (-40˚ to 50˚C) operating; -40˚ to 167˚F (-40˚ to 75˚C) storage
Surface Sensors
Pressure Transducer 4 - 20 mA current loop; certified intrinsically safe Class 1 Division 1, Class 1 Zone 0
-40˚ to 250˚F (-40˚ to 121˚C) operating; -67˚ to 302˚F (-55˚ to 150˚C) storage
Hook Load Sensor 4 - 20 mA current loop; certified intrinsically safe Class 1 Division 1, Class 1 Zone 0
-40˚ to 180˚F (-40˚ to 80˚C) operating; -40˚ to 257˚F (-40˚ to 125˚C) storage
Depth Encoder Standard NAMUR Type; certified intrinsically safe Class 1 Zone 0
-40˚ to 180˚F (-40˚ to 80˚C) operating; -40˚ to 257˚F (-40˚ to 125˚C) storage

Application

Application MWD Tool Gamma Sensor SIU 2 SIU 2 with DTS option PC* with SureShot Software Printrex Plotter Rig Floor Display Surface Sensors**
Pressure Hook Load Depth
Survey-on-connection              
MWD          
Gamma/LWD  

Request more information about Surface System Hardware

Fill out the form below. A sales representative will be in touch with you shortly.


Contact us